Loading..
Welcome to visitors

Switch POE 16+1 Tenda TEF1118P-16-150W

  • Brands Tenda
  • Product Code: TEF1118P-16-150W
  • Availability: 1

TEF1118P-16-150W / Switch / 16 10/100Mbps +1 Gigabit/SFP Slots Switch With 16-Port PoE


TEF1118P-16-150W is a Tenda PoE switch that offers 16 10/100 Mbps Base-TX RJ45 ports, 1 10/100/1000 Mbps Base-T RJ45 ports, and 1 1000 Mbps Base-X SFP port. Ports 1-16 comply with the IEEE 802.3af standard (maximum PoE power output: 15.4 W) and 802.3at standard (maximum PoE power output: 30 W). The switch offers a maximum PoE power output of 135 W and can supply power to and exchange data with APs, IP cameras, and IP phones through CAT5 cables. It also provides simple management modes such as CCTV, VLAN, and Extend to help reduce cabling costs of IP terminals like APs and IP cameras.




SPECIFICATION
Standard&Protocol
IEEE 802.3、 IEEE 802.3u、IEEE 802.3x、IEEE 802.3af
MTBF
≥100,000hours
Indicator
16*Link/Act per device
1*G1 Link/Act per device 
1*SFP Link/Act per device 
1*PoE-MAX per device 
1*Power per device
Interface
16 10/100Base-TX ports(Data/Power) 
1 10/100/1000Base-T port(Data) 
1 1000Base-X SFP port
Lightning Protection
6KV
Store & Forward
Yes
exchange capacity
7.2 Gbit/s
Packet Forwarding Rate
5.36Mpps
MAC Address Table
4K
PoE supply management
Port 1 to Port 16 support IEEE802.3at/af POE standard
PN pass-through
1 2 4 5 +,3 6 7 8 -
Input Power
AC:100-240V~ 50/60Hz
Dimension
294*178*44mm( W x D x H )
Power Consumption
in full configuration:<150W
PoE Max Power Supply:135W
Ports feature
CCTV: 1-8 ports based CoS, If multiple IP cameras are connected to the switch, you are recommended to enable this mode and connect the G1 or SFP1 port of this switch to the upstream device to which the monitoring computer connects. This ensures smoother monitoring video playback.
Standard: the switch functions as a common unmanaged switch and all the ports of the switch can communicate with each other.
VLAN: In this mode,1-16 ports of the switch cannot communicate with each other, but can communicate with the G1 and SFP1 ports.Solid DIP switch to isolate ports to prevent broadcast storm and defend DHCP spoofing.
Extend: In this mode, the data rate of 1-8 port of the switch is limited to 10 Mbps, whereas the maximum transmission distance of the port is increased to 250 meters. All the ports of the switch can communicate with each other.
Environment
Operating Temperature: 0℃~40℃ (32℉~104℉)
Storage Temperature: -40℃~70℃ (-40℉~158℉)
Operating Humidity: 10%~90% non-condensing
Storage Humidity: 5%~90% non-condensing

Write a review

Note: HTML is not translated!
    Bad           Good